Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Click here to ask your question

combi boiler pressure loss?

baxi 80e combi losing pressure. Only used to lose pressure with heating on. Used to have to top up every couple of weeks, now every 2 days, 1.5 bars to 0.3 in 2 days.
No visible leaks upstairs so had plumber round to check below floorboards and found no leak.
Topped up to 1.5 bar shut off flow and return to rads.
Pressure dropped to 1.1 over a few days of using hot taps then has remained at 1.1 for several days.
Just turned flow and return back on and the pressure remained at 1.1.
At a loss to work out whats going on.
No discharge out of over flow (put condom over it).
Boiler serviced a few months ago engineer said to try fernox leak sealer but no joy.
gameoverman, April 2009
We had a similar problem - a couple of radiators had minor leaks. However as leak only occured when radiator was on the water evaporated before it caused a damp spot. We only found the issue when we took a radiator off the wall to decorate and there was a rusty water mark on the wall. We then checked all the radiators and found the same/ similar on one other. Plumber fixed the radiators and the boiler now holds its pressure when the heating is on.

Samstan, December 2009
Thanks Keith, but there's nothing coming out of pressure relief valve or anywhere else visible, as I said had floorboards up downstairs but plumber couldn't see any leak and was pretty adamant there wasn't. Could he of missed somewhere I'm thinking? as it can't be upstairs as with the volume that's going surely we would notice.
Don't know if it's possible but could the boiler be evaporating the water?

gameoverman, April 2009
check the pressure relief valves not leaking water,its a 15mm pipe from the boiler through the outside wall into drain onto the ground.
check all rad valves beneath the control knobs for leaks.
check behind the drop down facia lhs for leaks.

keith brown, April 2009