Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Click here to ask your question

Potterton Prima 40f?

Boiler ignites and burners come on with 10mbar burner pressure. However looking through the view glass I get flame lift off. I have changed the fan cleared the pilot assembly blown through the air pressure tubes and checked out the integrity of the flue. I still get flame lift off followed by the burners going out.This cycle then continues. Help
Jack, May 2009
Previous post absolutely correct, potterton make a Renovation kit for the flue terminal which consists of a sleeve and new terminal, should take about ann hour to fit

www.elanar.co.uk, May 2009
Check the flue terminal , these flues had a tendency to rot around the inner flue at this point.

Ciaran, May 2009