andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

pressure on boiler keeps going up to over 3bar safety valve not c?

sabre 29he pressure keeps going up on gauge safetyvalve not coming into operation boiler still working ok have drained system down and refilled to 1.5bar switch on goes to over 3bar what could be problem be
john peden glasgow, May 2009
it could be the expansion tank has lost its charge or is faulty.the pressure would increase when the system started to get hot. to test the pressure make sure that the boiler is drained and test with a footpump and pressure guage should read between 0.5-1.0 bar. if the pressure goes up even when the heating is not on i would be looking at firstly the filling loop to make sure it is fully shut off.

pete, May 2009