Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Vokera Excell. Heating system ok but no hot water!!?

Our boiler is operating ok but we are not getting any hot water. If the boiler is not running,usually it kicks in when you turn the hot tap on. This is not happening. Radiators are all hot and working ok. The boiler is around 10 years old.
Gordon Crichton, January 2006
on hot water boiler fires up when tap turned on.have been told diverter valve has blockage and hot water going down central heating systum (vokra Excell 80e combi )

Trev, February 2012
hi, i agree with mike, but may i add that there is a micro switch that is operated by the diverter valve, when you turn on the tap the diaphram moves and trips the switch to start the boiler up, you should be able to here the switch click in and then see the boiler start,but if the diaphram is not moving very far ie about 4mm, then the switch will not operate.

bob roberts, January 2006
99 % definately the diaphragm common problem

mike, January 2006