When you changed the inlet valve you had to remove the control box to get the valve out. When you put the control box back you should of checked that the bowl was completely empty before connecting up the air pressure tube on the right hand side. What you need to do is open the panel & remove the air tube from it's connector. Then turn machine on & advance to final spin. Press start & run pump until all water finishes coming out of drain hose. Stop machine & put air tube back on to it's connector. Close panel & run machine as normal.
Lincoln Appliance NZ, June 2009