Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

Baxi 105e CH fires up but only hot water is selected?

baxi 105e, - only hot water is selected however sometimes the boiler fires up and the rads (ch) comes on. Not ideal in the summer. There is no indication on the boiler that the CH is on.
Any ideas ??
ade, July 2009
The o-rings in the 3 port diverter valve will be passing allowing the water that should remain in the boiler for the hot water to leak into the heating system. It may fire up by itself if you have the model with the water pre-heat, you could turn the pre-heat dial right down to fix temporarily.