Cass asked ... Replacing full bulb housing unit in Neff oven?    |    Pádraig O Sabhain asked ... How to fix Kenwood Slimline Dishwasher KDW45X20 with a F1 Er?    |    keith asked ... How to reset after battery change?    |    Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Click here to ask your question

how can i wire up a Micron PIR from maplin which has 7 terminals not 6?

my optima xm6 alarm has a faulty PIR which has 6 wires in 6 terminals.I bought a new Micron PIR from Maplin which has 7 terminals.How can I wire it up?
Alan phillips, July 2009
i found a broken wire under a carpet -ve.Repaired wire and alarm system now working perfectly with new PIR wired as suggested.Thanks for your support.

alan, July 2009
What makes you think your XM needs a n/o detector, it does not.
Wire the detector using the 6 wires forgetting the LED connection

acorn, July 2009
led

alan phillips, July 2009
Micro PIR:1=13+ve,2=-ve,3&4=n/c,5&6TT,7=led

alan phillips, July 2009
i think the problem is the optima xm6 has n/o contacts and the micro PIR has n/c contacts.is there any way round this because manual says there are n/o and n/c contacts?

Alan Phillips, July 2009
So you've worked out what 6 are, 2x 12v, 2x Alarm and 2x Tamper.

What is #7 marked as then, it's in the manual?

acorn, July 2009