GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

ACCENTA + G3 - PROBLEM AFTER POWER FAILURE with setting zones?

After a recent power failure my alarm seemed to restore itself to its factory settings. My code would not work, (but the original default code did) and the omitted zones were no longer in the memory (ie i only use 3 of the 8 zones, so the engineer programmed it to automatically omit the other 5 zones each time I set it.), but this does not appear to work now. I have managed to reset my code, however I dont know how to reset the zones. Can any one help?
Richard Brown, August 2009
if its been reset to factory settings, follow these steps
1.> Press the Prog button on the keypad
2.> Tap in 9999
3.> tap 5
4.> All the zone LED should now be flashing, select aa zone thats not being used (e.g zone 4)
5.> To Disable the zone Press 0 and then reset
6.> Repet steps 4-5 for every zone you need to disable and there you go
7.> just keep Taping the Reset button untill just the Day and Power LEDS' are lit and you have just fixed your problem

forde52, August 2009
so in your house you have 8 pir's or 3 ? well if you have only three zones in your house hold open the main panel and check the wires were the pir wires go
and if 5 of them have no wires in there or loops i.e
it should have the number of the zones between two lines because the pir's in the wire up to the zone with two wires and then they go into either aux or 13v 0v so if 5,6,7,8, are empty loop them with wire try that or try fuse speaker 13v

death, August 2009
link Click here to see other fixes for Accenta G3.