Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

how do i repressurise my sime super 80 boiler?

Sime super 80 boiler. No manual available.
I get hot water briefly in shower but no hot water elsewhere in the flat. the pressure guage on the front of the boiler is just above zero so i suspect the system pressure needs topping up. How is this done/
TOL, August 2009
The Sime is a superb boiler, I have one myself. Somewhere down the MAIN COLD WATER INPUT pipe there will be the filling loop. This should be an armoured pipe running between the COLD INPUT and the HEATING RETURN. depending on the variety of the filling loop you may need to either just turn a tap or you may need a screwdriver to open the valve. Becareful, watch the pressure guage as you don't want to achieve more than 1.5bar (max)

Some installers years ago did not install the armoured pipe. so you may find two regular bibcocks if so carry-out the same procedure but do it very gently. remember 1.5 = maximum when the system is cold.

Townteck, August 2009