Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

Linea Vokera 24 water pressure too high?

My Linea Vokera 24 boiler is not working. The water pressure is at 2. It's meant to be between 1 and 1.5. Is there anyway of repressurising the boiler?
Jack C, September 2009
you can do this by either finding a drain off on the system and letting some water out of the system or put a jug under one of the radiator bleed vents and open the vent with a radiator key. But dont take the pin all the way out Have someone to watch the gauge on the boiler until it drops to 1.5 bar make sure the boiler is off and cold before you start good luck

steve, September 2009