GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

potterton puma 80?

My Potterton Puma 80 is about 8 years old and has burned the pcb where the boiler + central heating switches connect to the pcb. Is this likely to be down to a pcb fault or could it be caused by something else ?
Roy, October 2009
i have the same thing as tony plez some one help us

anna, November 2009
The pilot is lit but the central heating does not work, the hot water works fine. Any suggestions

Tony, November 2009
Soldered one of the top corners a couple of years ago - the board is burned beyond repair this time. I have now replaced the pcb and 2 plugs one from the central heating switch and the other from the boiler switch as they were also damaged. Heating is now running fine - thanks for your reply Rob

Roy, October 2009
This is probably a dry joint on the board, check the neutral and live connections on the top left of the board as u look at it. You will probably find the neutral has a bad connection and needs soldering or replace the PCB if its really bad. Not to say its not another component causing the problem.

Rob, October 2009
link Click here to see other fixes for Potterton.