Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Fisher & Paykel MW512 5.5 kg smartdrive error code?

Can someone help with this error code please and what is the fix? 00XX000X. Thanks
Wayne, October 2009
I replaced the valves and no change

matt, September 2012
yes :)

Wayne, November 2009
Thank you very much for this advice, you are a champ. I will buy a multi meter. Are the valves able to be replaced separately if that proves to be the problem? Thanks again.

Wayne, November 2009
Error code 49. The Motor Control Module has measured a voltage from the valve diagnostic circuit that indicates the cold valve is faulty. Open the panel & check that the wiring plug on the cold inlet valve is firmly in place. If ok then check the valve coil with an ohms meter to see if it is open circuit. If wiring & valve are ok then it may be a fault with the control module but is more likely a valve fault.

Lincoln Appliance NZ, October 2009
link Click here to see other fixes for Fisher & Paykel.