Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

worcester 25 si roughly about 8 years old ?

what should the resistance across the solanoids of the gas valve of a worcester 25 si boiler . there are 3 of them.
hardie, November 2009
I presume you are checking the resistance to see if theres a fault on the gas valve. You can quite safely say that if there is 1000ohms or so the solenoids are ok, check theres voltage to the valve (do this with a hot tap open) if there is then it may be a fault with the valve internals i.e. stiking diaphram

nev, November 2009