katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Kathy asked ... Samsung ER-4915?    |    Mark asked ... Oven door removal?    |    Click here to ask your question

OPTIMA 701 Ferrori heating problem?

Everything is fine but not heating system.
My thermostat is on +17.5C, in room was +15.5C
Boiler switched on at 7am and heathing was for 5 min, then stopped and for next 30min- only pressure system was working, after 30min heating system switch on again for 1min ,and again only pressure system was working.
Sometimes I can hear when heating is on sound as like something wants to switch it off
In 1 hour temperature raised only 0.5C and radiators were almost cold
Do anyone got any idea what should I do?
Michael, November 2009
quite likely to be the central heating thermistor in the boiler , you can check this by removing the plug on connector from the sensor and swapping this with the hot water sensor, if this works you need a new thermistor, make sure you put the connectors back on the correct sensors after test.....

Brucey, November 2009