Toddy asked ... Pdw5048tms saw?    |    Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    Click here to ask your question

OPTIMA 701 Ferrori heating problem?

Everything is fine but not heating system.
My thermostat is on +17.5C, in room was +15.5C
Boiler switched on at 7am and heathing was for 5 min, then stopped and for next 30min- only pressure system was working, after 30min heating system switch on again for 1min ,and again only pressure system was working.
Sometimes I can hear when heating is on sound as like something wants to switch it off
In 1 hour temperature raised only 0.5C and radiators were almost cold
Do anyone got any idea what should I do?
Michael, November 2009
quite likely to be the central heating thermistor in the boiler , you can check this by removing the plug on connector from the sensor and swapping this with the hot water sensor, if this works you need a new thermistor, make sure you put the connectors back on the correct sensors after test.....

Brucey, November 2009
link Click here to see other fixes for Ferrori OPTIMA 701.