Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

Firebird Riello RDB burner photocell sooting up?

I've got a firebird c20 condensing boiler with the Riello RDB burner. The photocell keeps sooting up every three-four days use. This has been going on for over a year. Had 5 engineer visits from two service companies, replaced the cell, stripped the boiler everytime, replaced oil in tank, fitted extra filter in the oil line, loads of printouts stuck to the boiler from gas analysis etc to check its running ok but nothing has worked the cell soots up again and again. What do I do? replace the burner? Any ideas?
Steve, November 2009
Hi i had a similar problem after mine was cleaned. Check the baffle plates in the boiler the serated edges should be one facing out, one facing in, one facing out.

malcolm, December 2009