GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

ive got a baxi 105e ?

ive got a baxi 105e and when the heating is on the pressure shoots up to 3.5 bar and the water discharges through the pressure relief valve so needs topping up every day
steve, November 2009
OOPS. Sorry it is the safety relief valve (one end is red).

Chantal Bristow, December 2009
we had just the same problem and our E-On technician came and found the fault. He had to change the SAFETY VALVE -3 bar, chich he did after removing nearly a bucket full of water accumulated in the boiler.

Chantal Bristow, December 2009
repressurise the expansion vessel
if that doesnt work replace it

b, November 2009
link Click here to see other fixes for Baxi 105E.