sorry mike and the mechanics for taking so long to reply to your answer. the boiler is a 30/50b. I tried your suggestion no joy with shorting the hi limit stat, when i took the pilot light ass to the spares place, he said that there was nothing wrong with it! A new gas valve, another thermo couple, a new pilot light ass later the boiler works!! (but only with the hi/lo switch set to low). The chap who came out to fix it said"it could be the hi/lo switch, or it could be an electrical fault which will mean a new boiler"! Any suggestions would be welcome
birdmantom, December 2009