GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Glow-worm 30HXI F5 fault code - cannot restart boiler?

When I switch off, turn the RHS switch to 0 and the LHS switch to off and pause as instructed, it usually starts again when I reverse the process. This has happened a couple of times in the last month.

Tonight it tries to start for a couple of seconds then fails. After a pause it makes a more convincing fist of it, but after about 15 seconds it fails completely.

I have taken off the front and the inner silver cover, but I cannot see anything else to press. I have read there is supposed to be a thermostadt reset switch in the top left corner of the box in diagram 10.2 of the servicing manual, but I cannot see anything useful to do with it.

Anyone got any bright ideas?
Mark, December 2009
take off the outer cover then then the inside coer exposing the fan/burner in the top left hand corner there is a thermostat with a red reset button press this to reset eror F5

john, November 2012
Top left red button small, between two black wires
push to reset.

paul, February 2011
And thank you Mick as well !

Mark, December 2009
Dear b

Many thanks. I could not see the red button, but fortified by your advice by your advice I pulled the front wire off and located the mid button by feel.
Success!

Bravo and thank you.

Mark

Mark, December 2009
its there your not a gas engineer thats why its hard to find if i remember its red and the size of a match head top left ish .cheers

mick, December 2009
is there a red button between 2 wires on the stat
top left
turn power off first

b, December 2009
link Click here to see other fixes for Glow-Worm.