GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Baxi duo tec combi 24HE heating fault?

My 2 1/2 year old Baxi combi shuts down the heating side despite everything calling for heat. This happens intermittently for no apparent reason and I usually discover it when the rads have gone cold! Despite being 'off' something is still running, pump or flue fan? I have to switch the main electricity switch to the boiler off and on again to rectify the problem, the boiler then firing up as normal. The hot running water side is not affected.
Troubled John, January 2010
hot water working , central heating not. any ideas? thanks

tony beno, March 2013
i have baxi duo tec 2 28ga installed in my home. my central heating is working properly but not hot water is coming. can anyone help?

awi, July 2012
How do i change the PCB in my baxi duo tec 33, fault E168.

APB, January 2011
there is a return filter fitted inside the nut on the jig /pipe connections //to do this and check for debris and sludge you need to isolate the 2 black taps under boiler black tap furtherst left and black tap furtherst right inside the boiler to the right of the pump is a small white wheel valve open up and drain boiler into bucket underneath you will get about a 5th of a bucket then when water stops undo the silver 1/2 " nut on the return pipe this is found above the right hand black tap you have isolated it sits facin you underneath remove and check for crap // when complete refit open taps and re pressure to 1.5 bar

tony, January 2010