GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

potterton kingfisher pilot light ok but boiler not lighting?

potterton kingfisher pilot light ok but boiler not lighting
no hot water or heating
tim, February 2010
The problem is a faulty gas v/v. these are available on the boiler spares websites. You can replace it or do what I did on my 35 year old boiler. Make sure you have 230/240v from the boiler thermostat to the gas v/v soleniod and the central heating is switched on with the room thermostat set higher than room temp. Also on the gas v/v make sure the pilot light plunger is fully raised, then hit the gas v/v with a shoe. It worked for me. This will free a sticky soleniod v/v inside the gas v/v. If the solenoid is burnt out it will not work. Hoping for another 35 years from my potterton Kingfisher!

geordie, November 2010
240v going to solenoid on gas valve ok, does this mean solenoid windings gone open circuit ? Pilot light ok.

Does anyone know if spares available to replace solenoid only ?

chris stockley, May 2010
Had the same problem on mine. Check the red button under the box with the 0-4 knob on it. Some kind of trip switch. Pressed it in on mine and all came back to life

Steve, February 2010
could be a faulty gas valve see if 240 volts going to it could also be a faulty thermostat have fixed lots of these old boilers

heat line mike, February 2010
link Click here to see other fixes for Potterton Kingfisher.