Toddy asked ... Pdw5048tms saw?    |    Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    Click here to ask your question

fuel saver 55f will not work every time?

fuel saver 55f trys to go I get about a second of power to the fan and then nothing I switch the thermostat on and off ten to twenty times and if Im lucky it starts up and keeps going, as soon as the thermostat turns off on its own the boiler goes off and the fan stops.
bob hardman, February 2010
i would take the case off and check the current to the fan, with a multimeter or at worst a neon screwdriver, if power is continuous but the fan stops and starts, your fan motor is at fault, if power is presant for only a second then cuts out, its probably the pcb or a supply lead, carefull not to touch any live connections when doing this and have someone at hand to switch power off in case the boiler does decide to fire up when you take the case off

john, February 2010
link Click here to see other fixes for 55F.