Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Reset optima to factory settings?

I already have a optima xm6 alarm system and need to return it to factory settings so it can be used. thanks
Bob, March 2010
O DEFAULT
1) Remove the mains power supply & cause a tamper condition by removing the control panel cover.
2) Remove all wires from the terminals 9 and 19 on the xm4 (terminal 13 and 23 on the xm6)
3) Fit a wire link between terminals 9 and 19 on the xm4 (terminal 13 and 23 on the xm6) & apply power.
4) The system will now power up with no alarm condition.
5) Leave for 30 seconds.
6) Remove wire links then replace the original wiring if any.
7) Refit the front cover checking that the tamper indicator goes off.
8) Press reset.
9) The system has now gone back to factory set conditions
10) EngCde 9999, CustCde 0123

acorn, March 2010
link Click here to see other fixes for Optima XM6.