Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Click here to ask your question

REFILLING A SEALED HEATING SYSTEM?

I have to remove some radiators from a combie system; takinging them off is fine but what do i need to do to fill the system back up when I replace them? I dont want to damage the boiler or the pump!
Jon, May 2006
turn the boiler off, re-fit the radiators. top the pressure up to 2 bar. go and bleed the rads till the pressure goes completely. then top the boiler up in 1 bar stages until you get water out of all the rads. Hey Presto!

craig, May 2006