GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Ariston microGenus He 32 mffi?

my boiler shows no water pressure E 02 error code .correct code for no water pressure . fill up system with built in filling loop fine .Boiler works normally for abouts 20 mins while the pressure gradually drops then same message . whilst the pressure is dropping you can hear the water running out of the condensate flexi hose which discharges in internal waste pipe .this is all clear . Ive emptied the perspex condensate trap and filled back up with cold water for air lock but on running system fills up with warm water and all the water and pressure flows out freely into a bucket from the now diconnected flexi discharge pipe . It seems the water just immediately starts to discharge on pressurising the system out of this pipe as soon as the refilled system kicks in and temporary runs hot water or heating untill it drains out again and shows no pressure E02 error message . Boiler is about 1 and a half years from new install old
Stu, March 2010
yip, you would just lose pressure and have a pretty much constant flow of water out of the condensate pipe whether the boiler was running or not.

Ian, April 2010
thx Ian If that has happened would the hot water and heating still work

stu, March 2010
sounds like the primary heat exchanger is burst allowing the system water to run down the condensate pipe. if so new heat exchanger required.

Ian, March 2010
link Click here to see other fixes for Ariston.