Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Jerry asked ... Alpine 7287?    |    Guy asked ... Gaggenau fridge alarm problem?    |    Click here to ask your question

thermostatic shower control not hot enough?

aqalisa midas 100 shower rail thermostat inacurate set at 50 tepid output ,temp input 62 degrees.?
blannysnr, April 2010
thanks brian thermostatic shower fixed .

blannysnr, April 2010
turn t/stat to max hold in that position whilst removing knob (screw in centre of knob ) turn brass spindle until maximum temp you req. is reached replace knob in same position i.e. you can't turn it passed the max temp you've set if you are not sure how to do this contact aqualisa for fitting instructions you can probably download them

brian, April 2010