John asked ... Scantronix 9450 box stuck shut?    |    Pekaye asked ... Clutch Cable change?    |    Richard asked ... Mountfield SP414 mower, revs too high?    |    Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Click here to ask your question

Biassi combi boiler won'r fire up?

My Biassi combi boiler suddenly stopped firing up. When heating or water is turned on, it sparks (until cutout after about 5 secs) but won't fire up. It appears there is no gas getting through to the burner.
Referring to the service manual, I have checked the modulating operator coil and the resistance is as should be, about 125 ohms. I then carried out the second check (also referred to as 'modulating operator coil check' in the manual) by measuring resistance across the 2 upper, then the 2 lower of the 5 connector pins located on the gas valve below the coil. The upper 2 were as should be, about 1250 ohms, but the lower 2, which should be about 3000 ohms give no reading at all, ie. an open circuit. So, do I need to replace the whole gas valve (about £120) or the coil (£30) or have I missed something?
Any help / advice much appreciated
Jamie, April 2010