18 mins ago rick asked ... How can I fix my portable Zenith DVP615 DVD player? When I p?    |    3 hours ago Jim asked ... How can I get my scarifier to work?    |    george crawford asked ... Citroen C3 Picasso?    |    Maggie asked ... How can i mend my kettle?    |    Anthony asked ... Can a crack be repaired?    |    Click here to ask your question

Biassi combi boiler won'r fire up?

My Biassi combi boiler suddenly stopped firing up. When heating or water is turned on, it sparks (until cutout after about 5 secs) but won't fire up. It appears there is no gas getting through to the burner.
Referring to the service manual, I have checked the modulating operator coil and the resistance is as should be, about 125 ohms. I then carried out the second check (also referred to as 'modulating operator coil check' in the manual) by measuring resistance across the 2 upper, then the 2 lower of the 5 connector pins located on the gas valve below the coil. The upper 2 were as should be, about 1250 ohms, but the lower 2, which should be about 3000 ohms give no reading at all, ie. an open circuit. So, do I need to replace the whole gas valve (about £120) or the coil (£30) or have I missed something?
Any help / advice much appreciated
Jamie, April 2010