Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Click here to ask your question

water pump problem?

i have swift kontikki motorhome does my pump always have to run ? or is it suposed to cut out when no water is running? if so whats the cause? anyone please?
kev, April 2010
The other thing in some is a pressure valve on the inlet cold needs adjusting. Turn it clockwise to close it then turn on a tap then open the pressure valve slowly until it starts clicking then stop turning the knob. Turn tap off and pump should stop.

bob, May 2010
1 have a 2002 avan, when i turn on the water pumpth , the water goes back out of the inlet instead of the tap , could the one way valve be broken?thank you.

ken, May 2010
Hi Kev, I've got an old K reg Swift Kontiki which had the same prob recently. The water pump should not run when all the domestic water taps are turned off. Each tap, hot and cold supplies in kitchen and bathroom, has its own microswitch fitted below each tap, below the work surface. Access can easily be gained by removing the tap unit and lifting it free a couple of inches. In your case it is possible that one of the microswitches has become detached from its mounting, if so it would then be in a continually 'on' situation! Start with the kitchen taps, remove the four screws and carefully lift the unit and check below. Replacement taps are available from the 'Whale Elegance' range on the Leisureshopdirect web site. Good Luck.

Stewart, May 2010