Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

reset loop?

hi guys,
just moved house which has got an 'ade optima compact, 8 zone panel' fitted.. with all the upheaval, i have lost the alarm code b4 i had chance 2 change it.. it is not like my older optima where u cud just power the panel down.. is there a loop where u can clear the 'nvm'..
regards
peter, June 2010
when i've done that acorn, i'll just programme my new code from factory default code of '0123'.. all i want is the loop to reset the panel to do it..

peter, June 2010
cheers peter but this is an 8 zone so wudn't first link be '17' to poss '31' (+ set) i know they went up in multiple of ten to the (+ set) link but this panel doesn't seem to do that.. i'm not sure whether try it or not as i don't want to risk damage to the panel
regards

peter, June 2010
When you've done that, how are you going to reprogramme it?

acorn, June 2010
- Remove mains supply and control panel
- Disconnect batery
- Remove wires from 9 & 19
- Link 9 & 19
- Re-apply power
- Powers up with no alarm and NVM is cleared and in test mode
- remove link from 9 & 19, replace original wires
Job done.

Peter, June 2010
Have got one of these, still boxed, will dig out the manual tomorrow and reply with the answer. In the meantime try browsing on-line for a manual.

Peter, June 2010
link Click here to see other fixes for Optima 8.