GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Worcester Bosch Heatslave 25/32 Combi Oil?

Worcester Bosch Heatslave 25/32 Combi Riello Burner, First off we bought this boiler about a year ago and moved to France thinking everything will work well. To then find out the normal heating fuel in france is 35 sec (red diesel) obviously this boiler wasn't meant to run on this fuel (meant to run on 28sec) but it did and worked perfectly for around 5 months. It then started to play up so took it apart and had noticed it had a large build up of black crap in it. It was cleaned out and it started working fine again. I then managed to find out that all it needed was the jet changing and the fuel pressure and air pressure setting up correctly and the boiler should work fine on the 35sec fuel, which we did. That had worked perfectly for another 5 months then woke up this morning and it had locked its self out. Had it apart again today, no black crap in it insides seem fine. checked photocell that seems to be working, checked ignition thats working, can't see a problem with fuel as bled the system and it's getting to the jet as there is fuel sitting in the combustion chamber. I have put it all back together and tried it again but all it does it lock out after 12 secs, with no real attempt to ignite. any suggestions would be greatly appreciated!?
Eddie, July 2010
my boiler has a blue flashing on it, no heating!! on the display panel it is saying 9F and 855 with an explanation mark in a triangle. I reset it boiler goes back to normal for a few minutes then starts flashing again please help??

Sarah, December 2014
does this still work ?

jones, December 2014
we had a similar problem recently with a worscester heatslave oil bioler - it was the external oil valve that needed replacing. It kept shutting off the flow of oil to the boiler.

daryn, July 2010
Hi, this is Worcester, Bosch Group

Although we don't currently offer live technical support online, our Technical Support department will be able to help. Their number is ++44(0)844 892 3366 - they're open 6 days a week and on average answer calls within 20 seconds.

Worcester, Bosch Group, July 2010
link Click here to see other fixes for Worcester.