GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

fault with veritas 8c?

in my garage i have a texecom veritas 8c panel with a rkp at the front of the garage i hate two sensors 2 door contacts and 1 shock sensor

in the middle of the night it always seems to go off and when i turn it off 1,3,5 lights come on thats a sensor , shock sensor and the door no 1 is entering the garage at night ive just replaced the battery and its still doing it ive reset it all but still nothing can anyone help me resolve the problem
help please, August 2010
fit a 4 microfarad capacitor across the mains input in panel,(make sure that you turn mains off first,)and that it is the plastic cased type,if its a voltage spike,this will take care of it,if this not work,then you have a problem with the panel,

gts, August 2010
test meter time.
Check all supply voltages, charging rates. Cable resistance.
Earth faults. Induced AC.

Alarm, August 2010
yes it does a sensor light outside is always on (not lit up ) but when you walk past it coemes on ? but thats all

and no not at the same time last night 2:30 night before 7:30 in the morning

help please, August 2010
Is it at the same time every night?
Could be a mains spike.Check time clocks to see if anything turns on/off at the same time as the alarm events.

Alarm, August 2010
link Click here to see other fixes for Veritas.