Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Honeywell Accenta G4 Wired Intruder Alarm - one PIR does not work?

Newly installed professionally and worked fine. Now one PIR does not show the red flashing light and when set shows an error message. Any suggestions on what to check? Someone said to check the fuse in the control pannel. I don't want to open the pannel till I can know where this fuse might be. Any suggestions or where can I see a schmatic diagram?
Les, October 2010
red and green flashing light but the pir does not work after the walk test

TEOFILO MONTENEGRO, August 2014
Hi Les
It sounds as though you may have a faulty sensor and this is why you cannot set the system also.
If this is the case you just need the following:

1: competent engineer to put your system into engineers mode
2: you can then safely check and replace the pir without the system locking out and going into tamper alarm when attemp[ting any work on system
3: reset and test panel and away you go!
4:Any help with this just let me know

Alex, October 2010