Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

Glow Worm 30ci F5 Error (Red Light Flashing)?

I believe the system needs resetting as, from the research I've done so far, the unit overheated. However, I don't have a manual and I can't see anything obvious that could be a reset button. Anyone able to tell me exactly what I'm looking for and where it will be inside the unit, e.g. is it inside the control panel, fixed to the side of a pipe, etc.?
Peter S, October 2010
f5= overheat stat requires reseting. inside boiler top left, two wires with red button, with the power turned off, push in . its quite small about the size of 20p. this is a safty device, it means the boiler has reached 90oc. dont keep on resetting. call expert.

andy the gas man, October 2010