Blaablaa asked ... How can I fix?    |    pete asked ... Flymo 330 turboglide?    |    keith asked ... Fuseboard( s) location of renault trafic t1100 1993?    |    Janet asked ... Neff B1641 door not closing at top?    |    Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Click here to ask your question

How can I fix my F&P intuitive Eco IW812, error code 49?

How can I fix my F&P intuitive Eco IW812, error code 49? I am a sparkie in a remote rural area so any info on what component is u/s would be great.

Thanks
john, October 2010
The control board is getting an incorrect voltage reading from the cold inlet valve. Check that the wiring plug is properly connected to the valve. Check the valve solenoid coil for 64 ohms. May be caused by a faulty solenoid coil but can also be caused by a fault in the PCB control board itself which will probably mean replacing it.

Mk, October 2010