1 hour ago Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

potterton combi 80?

hello, my boiler has always had a slow hot w outlet that, once it has been on for a while is scalding hot.
I increased the cold w inlet thinking this would both improve the flow and cool it down which it did to a certain extent.
After a week or so the boiler seems to have developed a fault, the flame does not go out as it used to when the hot w outlet is turned off, it runs on for a minute or so making hising\ fizzing noises....eventually it goes out or the lockout is activated. opening a cold water tap elsewhere in the house seems to stop it.
I have turned the cold w back to its original flow but this has made no difference......
guy b, August 2006
CC thanks a lot for your time, will let you know how i get on

Regards
Guy

guy b, August 2006
The water flow switch needs replacing... You can sometimes get away with cleaning them up, but they only normally last a few more months before totally giving up the ghost.

ccMods, August 2006
link Click here to see other fixes for Potterton.