Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

Vokera 80SP overflows?

Hi The pressure keeps dropping and I can see water going out the overflow! If I top up the pressure/water the boiler works OK but the the pressure drops and .... Is this somthing I can fix. Any ideas pls.
Phill, December 2010
Thanks for the advice. I will try that.

Phill, December 2010
Thanks for the advice. I will try that.

Phill, December 2010
Thanks for the advice. I will try that.

Phill, December 2010
If the pressure goes up far when the central heating is on then the expansion vessel needs recharging. If it has been flat for long enough the regular overpressure valve operation could result in a drip. You can repressurise the expansion vessel yourself, or get a gas man to do it. Connect a car tyre type pump to the valve on the top of the big red vessel behind the boiler at the top. release all system pressure by twisting the red overflow valve top, pump up the air pressure till you get 12 psi or so on the air pressure guage >>WHILE KEEPING 0 PRESSURE ON THE FRONT PANEL GAUGE

c+, December 2010