Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

greenstar Ri boiler green light flashing ?

heating not working I reset thermostat boiler started up red light came on main switch then after a few minutes boiler stopped.
george blake, December 2010
According the user manual - "CONDENSATE DRAIN
This is a condensing boiler and the
terminal will, at times give out a plume of
water vapour. This is quite normal.
The boiler also produces quantities of
condensate which is discharged regularly
by a syphon within the boiler via a pipe to
drain. This pipe must not be blocked or
altered in any way." Is your pipe insulated ? If not, the water may be frozen during the cold weather in the last few weeks ? Try to de-ice with the hairdryer and/or warm water . Make sure you use the circuit breaker when you use the hairdryer and remember water and electricity do not go well together ! Good luck

Peter_Charlie, December 2010