Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

i get intermitant hot water when tap on?

i have a vaillant 824e turbomax when i run hot water tap i get hot cold hot water ,the boiler turns off in between what can b faulty thx
nari, January 2011
When running the tap, watch the temperature display on the boiler, if it reaches (approximately) 84c before shutting down then coming in again at 70-80c you have a blockage in the domestic plate heat exchanger