Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

New Holland M153?

error code 6 is displayed for the 3pl system what could the problem be?
Trent, February 2011
You mean error code 6 for 3 pt.
Slip control voltage low(short or open circuit) for Power, Range & Dual Command Transmissions.
Check the wiring & connectors is all that you can basically do, as you will need a multimeter & know which connectors to check the resistance of the EDC control panel which should be between 80-340 ohms when turning the slip control fully clockwise otherwise it's faulty.

Warren, February 2011
link Click here to see other fixes for New Holland.