Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Larry asked ... How to stop my steam iron from leaking. Model dw2463 Rowenta?    |    HT asked ... Radio code Philips 22RC200/35?    |    Click here to ask your question

worcester bosch 28cdi DHW problems?

Hi, having had at least a couple of years good use of this boiler,recently the hot water when run for 2 or 3 minutes, goes cold. the boiler cuts out and then within a few seconds relights and heats the water for 2 or 3 minutes then cuts out again ( very annoying when in the shower and impossible to have a warm bath !). i have checked the diverter valve which hits the microswitch and stays there until the tap is turned off. This occurs however hot you set the water temperature. Anyone got any ideas what the problem could be ?
James, September 2006
the pipe from the red cylinder to the pump is red hot, the pump gets very hot and the pipe leading from the pump is warm, trips off and resets itself after a cooling down periond

russ70, December 2010
my worcester 28cdi trips after a few minutes pump seems to work and new heat diverter just been fitted.

bar pressure raises to 2 bar after tripping and there is a gurgling noise prior the trip

the system does not seem to be circulating

russ70, December 2010
Hi there it sounds like the plate to plate heat exchanger is blocked. If this is blocked then the water will only get luke warm and the boiler will keep firing on and off. Try a new heat exchanger easy to change aswell on the cdi.

Mark man, November 2007
Hi there it sounds like the plate to plate heat exchanger is blocked. If this is blocked then the water will only get luke warm and the boiler will keep firing on and off. Try a new heat exchanger easy to change aswell on the cdi.

Mark man, November 2007
link Click here to see other fixes for Worcester.