Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

the bar pressure is 0 where is the valve located to pressurise the system?

no pressure in system i put stop leak into two rads.always having to bleed upstairs rads which are half empty and noisey.im looking to fill system with more water to get pressure back in pressure valve which is 0 at moment .i have a potterton prima f is the tap in boiler or outside it?
jimmy, April 2011
A Prima F boiler (generally speaking), will be fitted to an open vented system so doesn't have a filling point, it fills via the F&E cistern (probably in the loft).

It's possible that the ball valve on the system is stuck closed or the cold feed that fills the system is blocked.

However, if the system has been modified and fitted to a pressurised set up and you have a guage reading 0, the filling point should be located close to the guage, there would also be an expansion vessel nearby too.

Carefree, April 2011