andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

how can i fix my ferroli domicompact f 24 b boiler?

when the thermostat calls for heat the boiler fires up but after a short time it switches off and the fault display code reads F3 most of the time but at other times boiler switches off and the fault reads F3.
when using for hot water only there is no problem
corkball, May 2011
F3 fault

-heat sensor damaged
-check the correct positioning & operation of the heating sensor

-no water circulation in the system
-check the pump

-air in the system
-vent the system

to summarise
check your system pressure at least 1.5bar
bleed all rads
listen for pump running

manwithnoname, May 2011