Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Click here to ask your question

ADT 3200 plus F6 fault how do you clear it?

F6 fault how do you clear it.
Michelle Dodds, August 2011
Here, I've just realised, same two questions two different (?) people ?

Get ADT out, they're your alarm company, or better still read your manual.

acorn, August 2011
The fault displays shown on that panel

If you can see the display you mention, please point it out

(I'm not going to print this lot again)

c1 to 8 Detector circuit open.
t1 to 8 Circuit tamper open.
o1 to 8 Detector circuit omitted (isolated).
E1 to 8 Entry via a detector circuit.
S1 to 8 Detector circuit on Soak test.
EA Alarm on entry
EF Exit fault
bF Control panel battery fault
PF Mains supply failure.
Sr System reset (Total power failure).
AP Aux. (Detector) power failure.
Lb Control panel low battery.
rt Illegal use of keypad (excess number of keypresses).
rP Remote keypad missing.
rr Total power failure (engineer reset required).
u1 to u9 User access number (U5 = Duress, U9 = Keyswitch)
AE Access Engineer
AA Arm area A (Full set).
Ab Arm area B (Part set).
Ac Arm area C (Part set)
Lt Control panel tamper.
tr External bell tamper.
cF Communications failure (External signalling).
LF Telephone line fault.
cc Communications completed successfully.

acorn, August 2011
link Click here to see other fixes for Plus.