narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

Replacing simmerstat in F&P classic oven?

Need to replace original white ego 50 55073 002 dual simmerstat with new mdp110. Different configuration. Can you help with what wire goes where? Thanks
clive, August 2011
The mdp110 will be marked next to the terminals with : phase, N, load 1 & load 2.
Normal wiring would be Brown wire (power in) to phase terminal. Blue wire (neutral) to N. Two wires going to element (usually white or red) to load 1 & load 2. If you find the double element is the reverse of what it was before then swap load 1 & 2 wires around.