Sharma asked ... Replacing pin for belt guard Ranch King Pro 14AT818H205?    |    Freya asked ... Frister & Rossman Cub7 Sewing Machine?    |    katlego asked ... Rev count on my 1982?    |    andrew asked ... "SECURE" on a yellow backround, and I cant ge?    |    Melodie asked ... How do I remove and change the basket? Duratech Identity Gu?    |    Click here to ask your question

how do i fix flame lift on my ariston genus system boiler?

had an intermitent fault since it was new ,cant seem to get it sorted out now the fault is constant . The boiler lights ok and the fans working but it seems to keep going into flame lift but if i put it on test at maximum flame its fine, and when it comes off test it goes into flame lift again. any ideas? cheers
nath, November 2011
Disconnect the ionisation sensor, see if you get the same fault, if so most likely the PCB,not recognising the negative ions through the electrodes

Willgas, December 2020
Sounds like it could be the inlet gas pressure is incorrect, either the gas regulator on the meter is faulty of the boiler is not modulating properly so either burner pressure incorrect or pcb fault.

Steve, November 2011