GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

britony combi se no flame detected?

our boiler has come up with the no flame detected warning. we have tried the reset button & the pressure is ok, but it is still not working. does anyone have any ideas?
smiffy, May 2012
pump runs
fan runs
no sparking
if gas valve is opening would suggest APS is working OK
then would concentrate on spark generator & ignition electrode
if gas valve is not opening would check APS & PCB

manwithnoname, May 2012
doesn't ignite at all,
yes, yes & no

smiffy, May 2012
"sounds like its going to light as normal"
it sounds as though your saying its not even igniting
so lets check the ignition sequence
can you hear the pump run? YES/NO
can you hear the fan run? YES/NO
can you hear sparking? YES/NO

manwithnoname, May 2012
sorry not sure what model it is.
yes lights 70 & 80 are flashing.
sounds likeit's going to ignite as normal,
then after about 5 seconds the red warning
light & the 70/80 lights come on

smiffy, May 2012
britony combi SE [80 or 100?]
GCN 47-980-[16 or 17]
no flame detected
presumably LEDs 70 & 80 are flashing
boiler not firing at all normally means checking gas supply & ignition system
boiler firing but not staying on means checking flame detection system

manwithnoname, May 2012
link Click here to see other fixes for Britony Combi SE.