Baxi combi 105 HE?

Hi, I can only get hot water at the tap when the central heating is on. The pressure switch works but the pin doesn't come out to press it.
Any ideas?
Thanks,Roy.
Roy, May 2012
this advice is aimed at giving you an idea of cause of boiler fault
its not intended for you to attempt to repair boiler yourself
rather for you to get someone qualified to carry out repair with the prior knowledge of cause & cost

manwithnoname, May 2012
Thanks very much,I'll try that.

Roy., May 2012
baxi combi [instant?]105HE
GCN 47-075-19
CH OK
NO DHW unless CH ON
diaphragm on DHW differential valve needs replacing
installation manual
page 38
fig 69

manwithnoname, May 2012