Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Click here to ask your question

Boiler keeps over presureising?

I have a main 24he and it keeps building presure and releasing throgh the presure relif valve. I have replased this valve but the fault came back. I have checked the filling loop and this is not letting bye. So I then replaced the expansion vesal and refilled to 1.5 bar of air and then refilled the bolier to 1.5 bar and left overnight. On checking today the presure is back up to 3 bar and letting off through the presure relief valve. I have released this presure and reset to 1.5 bar, any ideas?
John cherry, May 2012
drain your boiler let the air out of the exspansion vassal
and only put in .5bar in the exspansion vassal refillthe boiler and it will be ok

KEVIN, May 2012
link Click here to see other fixes for Main 24HE.