andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

how to fix 537/i combi boiler?

presssure is at 2 temp is 40 untill tap goes on and it drops. water comes on warm then goes cold. fault display message is EA which is no pilot light. how do i turn that back on???
sheena, July 2012
EA fault
boiler is....
-failing to ignite
or
-failing to detect ignition
or
-gas supply problem
or
-flue problem
or
-condensate blocked
or
-pcb problem

could be any one of these
would have to systematically check & eliminate them

you dont have to dismantle the boiler to check
just use visual & auditory clues

can you hear the fan & pump spinning?
can you see/hear sparking?

AWOL, July 2012