Bosch 1200 Classix has been fitted with new brushes and the belt and door lock are ok.
the machine drains and fills.
The drum doesn't rotate on any cycle or spin.
any ideas
1)Brushes not fully down to touch armature. 2)Non ressettable overheat thermal fuse blown in brushplate. 3) control unit fault. 1) and 2) most likely, you need to be able to test for continuity with a meter for 2) ... Cheers