Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

scantroni 9500?

The alarm is triggered everytime it is set with exit fault
displayed on pannel,All system test works- change battery as well.
Girish, October 2012
classic door contact fault,check it,or as e manno asked,check what ever is the final door sensor

gts, October 2012
Sorry op just realised it's the four branch with LIM's,

You really need an engineer in to run full diagnostics,it's an old panel but you should really have it on a maintenance contract.

Hope when you replaced the battery you powered back up with battery first then mains?

Seen both versions of the 9500 with blown pcb's because they haven't been booted battery first, plays a nice tune on LIM test, depending on software running though.

I suggest getting engineer in who knows this system, but stick around mate, you may get a more positive answer.

Good luck.

e manno, October 2012
When set,you are leaving by the correct exit route ?.

e manno, October 2012
So a walk test didn't reveal any open circuits?,

Check timers in engineering,

Did you have this issue before you replaced the battery and what type of sensor have you for final exit, eg PIR, door reed, or final set button.

e manno, October 2012